Fluke-1507, 1503 절연저항
미터 |
|
|
절연저항 테스터기
원격프루브를 사용하여 프루브에서 절연테스트를 할 수
있습니다.
*절연저항 측정
1507: 0.01 MΩ to 10 GΩ 1503: 0.1
MΩ to 2000 MΩ
* 테스트 전압
1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000 V
* 전압측정 : 0.1 V to 600 V
* 전류측정 : 200
mA
* 저항측정 : 0.01 Ω to 20.00 kΩ
* 오토OFF 기능
* 30V 이상에서 측정시
경고
| |
|
제품설명
|
AC/DC Voltage Measurement |
Accuracy |
Range |
600.0 V |
Resolution |
0.1 V |
50 Hz to 400 Hz ± (% of Rdg + Digits) |
± (2 % + 3) | |
Input impedance |
|
Common mode rejection ratio (1 kΩ
unbalanced): |
|
> 60 dB at dc, 50 or 60
Hz | |
Overload Protection |
|
Earth bond resistance measurement |
Range/Resolution |
20.00 Ω |
0.01 Ω |
200.0 Ω |
0.1 Ω |
2000 Ω |
1.0 Ω |
20.00 kΩ |
0.01 kΩ | |
Accuracy |
|
Overload Protection |
|
Open Circuit Test Voltage |
|
Short circuit current |
|
Earth bond resistance
measurement |
Range/Resolution |
20.00 Ω |
0.01 Ω |
200.0 Ω |
0.1 Ω |
2000 Ω |
1.0 Ω |
20.00 kΩ |
0.01 kΩ | |
Accuracy |
|
Overload Protection |
|
Open Circuit Test Voltage |
|
Short circuit current |
|
General Specifications |
Maximum voltage applied to any terminal: |
|
Storage Temperature |
|
-40 °C to 60 °C (-40 °F to 140
°F) | |
Operating Temperature |
|
-20 °C to 55 °C (-4 °F to 131
°F) | |
Temperature Coefficient |
|
0.05 x (specified accuracy) per °C for temperatures <
18 °C or > 28 °C (< 64 °F or > 82
°F) | |
Relative Humidity |
|
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) |
|
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) |
|
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131
°F) | |
Vibration |
|
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2
instrument | |
Shock |
|
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop
test, six sides, oak floor) | |
Electromagnetic compatibility: |
|
In an RF field of 3 V/M, accuracy = specified accuracy
(EN 61326-1:1997) | |
Safety |
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement
category IV 600 V (CAT IV) | |
Certifications: |
|
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per
standard IEC/EN 61010-1 2nd Edition | |
Batteries |
|
Four AA batteries (NEDA 15A or IEC
LR6) | |
Battery Life |
Insulation test use: |
Tester can perform at least 1000 insulation tests with
fresh alkaline batteries at room temperature. These are standard tests of 1000 V
into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
Resistance measurements: |
Tester can perform at least 2500 earth bond resistance
measurements with fresh alkaline batteries at room temperature. These are
standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds
off. | |
Size |
|
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x
8.00 in L) | |
Weight |
|
IP Rating |
|
Altitude |
Operating: |
2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-operating (storage): |
12,000 m | |
Over-range capability: |
|
Included accessories: |
|
TL224 Test Leads, TP74 Test Probes, clips PN 1958654
(red) and PN 1958646 (black), holster and remote
probe | | | | |